Alcon, Inc. - Types BTC and BT90C Aluminum Multiple Terminal
Call Us: 513.722.1037  |  E-mail Us: alconinc@fuse.net
of Ohio Manufacturers Custom Overhead & Underground Distribution Utility Connectors
Our Products :: Hot Tap Clamps :: Hot Line Stirrup Clamp :: Parallel Tap Connectors :: Stud Terminals :: Pedestal Terminals :: Multiple Terminals :: Insulated Subsurface Terminals :: Insulated Pedestal Terminals :: Lugs :: Covers
Search Catalog :
GO
Use a (*) to broaden your search results
All Categories > Lugs > Type B2L and B4L Aluminum Multiple Conductor Lug > Type HTC and HTC2 Aluminum Hot Tap Clamps > Type VBTOT and VBTT 5/8" - 11 Stud Aluminum Multiple Terminal > Type VPB Insulated Subsurface Terminal > Type T4 Multiple Tee Tap Connector > Types BTC and BT90C Aluminum Multiple Terminal > View Items 

Types BTC and BT90C Aluminum Multiple Terminal

 width=
Check up to five results to perform an action.  width=


Aluminum and Copper Conductors
For Use With Copper Alloy Eye-Bolt Terminals
Fabricated from 6061-T6 Aluminum. Screw alloy 6262-T9.
All Socket Screws have 5/16" Hex Wrench Socket.

Available with:
Round Bottom Screws - Add Suffix "RB".
Flat Bottom Screws - Add Suffix "F".
Disc Pressure Pads - Add Suffix "D".


IMG_0864

larger image
IMG_0863

larger image



    Print Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  
Request InformationCompare Items   Results per Page : 
  Results 26 - 48 of 48 1 2 

Item #

Type

Number of Conductors

Conductor Range

Copper Stud Diameter

Copper Stud Length

Screw Size

BT90C3-250 BT90C 3 250 to 6 AWG - KCM 0.500 in. 4 in. 5/8 to 18 in.
BT90C4-250 BT90C 4 250 to 6 AWG - KCM 0.500 in. 4 in. 5/8 to 18 in.
BT90C5-250 BT90C 5 250 to 6 AWG - KCM 0.500 in. 4 in. 5/8 to 18 in.
BT90C6-250 BT90C 6 250 to 6 AWG - KCM 0.500 in. 4 in. 5/8 to 18 in.
BT90C8-250 BT90C 8 250 to 6 AWG - KCM 0.500 in. 4 in. 5/8 to 18 in.
BT90C2-350 BT90C 2 350 to 6 AWG - KCM 0.500 in. 4 in. 5/8 to 18 in.
BT90C3-350 BT90C 3 350 to 6 AWG - KCM 0.500 in. 4 in. 5/8 to 18 in.
BT90C4-350 BT90C 4 350 to 6 AWG - KCM 0.500 in. 4 in. 5/8 to 18 in.
BT90C5-350 BT90C 5 350 to 6 AWG - KCM 0.500 in. 4 in. 5/8 to 18 in.
BT90C6-350 BT90C 6 350 to 6 AWG - KCM 0.500 in. 4 in. 5/8 to 18 in.
BT90C8-350 BT90C 8 350 to 6 AWG - KCM 0.500 in. 4 in. 5/8 to 18 in.
BT90C2-500 BT90C 2 500 to 2 AWG - KCM 0.750 in. 4.5 in. 3/4 to 16 in.
BT90C3-500 BT90C 3 500 to 2 AWG - KCM 0.750 in. 4.5 in. 3/4 to 16 in.
BT90C4-500 BT90C 4 500 to 2 AWG - KCM 0.750 in. 4.5 in. 11/16 to 16 in.
BT90C5-500 BT90C 5 500 to 2 AWG - KCM 0.750 in. 4.5 in. 11/16 to 16 in.
BT90C6-500 BT90C 6 500 to 2 AWG - KCM 0.750 in. 4.5 in. 11/16 to 16 in.
BT90C8-500 BT90C 8 500 to 2 AWG - KCM 0.750 in. 4.5 in. 11/16 to 16 in.
BT90C2-750 BT90C 2 750 to 1/0 AWG - KCM 0.750 in. 4.5 in. 15/16 to 16 in.
BT90C3-750 BT90C 3 750 to 1/0 AWG - KCM 0.750 in. 4.5 in. 15/16 to 16 in.
BT90C4-750 BT90C 4 750 to 1/0 AWG - KCM 0.750 in. 4.5 in. 15/16 to 16 in.
BT90C5-750 BT90C 5 750 to 1/0 AWG - KCM 0.750 in. 4.5 in. 3/4 to 16 in.
BT90C6-750 BT90C 6 750 to 1/0 AWG - KCM 0.750 in. 4.5 in. 3/4 to 16 in.
BT90C8-750 BT90C 8 750 to 1/0 AWG - KCM 0.750 in. 4.5 in. 3/4 to 16 in.
  Results 26 - 48 of 48 1 2 
Site created by ThomasNet Interactive, a division of ThomasNet.com
Alcon of Ohio Manufacturers Custom Overhead & Underground Distribution Utility Connectors